Well-Designed Gas Line Plumbing - Cold Formed Pipes, EN10219 S235JRH, S235J0H, S355JRH, S355J0H – Spiral
Well-Designed Gas Line Plumbing - Cold Formed Pipes, EN10219 S235JRH, S235J0H, S355JRH, S355J0H – Spiral Detail:
Mechanical Property
|
steel grade |
minimum yield strength |
Tensile strength |
Minimum elongation |
Minimum impact energy |
||||
|
Specified thickness |
Specified thickness |
Specified thickness |
at test temperature of |
|||||
|
<16 |
>16≤40 |
<3 |
≥3≤40 |
≤40 |
-20℃ |
0℃ |
20℃ |
|
| S235JRH |
235 |
225 |
360-510 |
360-510 |
24 |
- |
- |
27 |
| S275J0H |
275 |
265 |
430-580 |
410-560 |
20 |
- |
27 |
- |
| S275J2H |
27 |
- |
- |
|||||
| S355J0H |
365 |
345 |
510-680 |
470-630 |
20 |
- |
27 |
- |
| S355J2H |
27 |
- |
- |
|||||
| S355K2H |
40 |
- |
- |
|||||
Chemical Composition
|
Steel grade |
Type of de-oxidation a |
% by mass, maximum |
||||||
|
Steel name |
Steel number |
C |
C |
Si |
Mn |
P |
S |
Nb |
|
S235JRH |
1.0039 |
FF |
0,17 |
— |
1,40 |
0,040 |
0,040 |
0.009 |
|
S275J0H |
1.0149 |
FF |
0,20 |
— |
1,50 |
0,035 |
0,035 |
0,009 |
|
S275J2H |
1.0138 |
FF |
0,20 |
— |
1,50 |
0,030 |
0,030 |
— |
|
S355J0H |
1.0547 |
FF |
0,22 |
0,55 |
1,60 |
0,035 |
0,035 |
0,009 |
|
S355J2H |
1.0576 |
FF |
0,22 |
0,55 |
1,60 |
0,030 |
0,030 |
— |
|
S355K2H |
1.0512 |
FF |
0,22 |
0,55 |
1,60 |
0,030 |
0,030 |
— |
|
a. The deoxidation method is designated as follows: FF: Fully killed steel containing nitrogen binding elements in amounts sufficient to bind available nitrogen (e.g. min. 0,020 % total Al or 0,015 % soluble Al). b. The maximum value for nitrogen does not apply if the chemical composition shows a minimum total Al content of 0,020 % with a minimum Al/N ratio of 2:1, or if sufficient other N-binding elements are present. The N-binding elements shall be recorded in the Inspection Document. |
||||||||
Hydrostatic Test
Each length of pipe shall be tested by the manufacturer to a hydrostatic pressure that will produce in the pipe wall a stress of not less than 60% of the specified minimum yield strength at room temperature. The pressure shall be determined by the following equation:
P=2St/D
Permissible Variations In Weights and Dimensions
Each length of pipe shall be weighed separately and its weight shall not vary more than 10% over or 5.5% under its theoretical weight, calculated using its length and its weight per unit length
The outside diameter shall not vary more than ±1% from the specified nominal outside diameter
Wall thickness at any point shall not more than 12.5% under the specified wall thickness
Product detail pictures:
Related Product Guide:
To become the stage of realizing dreams of our employees! To build a happier, much more united and far more professional team! To reach a mutual profit of our clients, suppliers, the society and ourselves for Well-Designed Gas Line Plumbing - Cold Formed Pipes, EN10219 S235JRH, S235J0H, S355JRH, S355J0H – Spiral , The product will supply to all over the world, such as: Mexico, luzern, Amman, Look forward to the future, we'll focus more on the brand building and promotion . And in the process of our brand global strategic layout we welcome more and more partners join us, work together with us based on mutual benefit. Let's develop market by fully utilizing our in depth advantages and strive for building.
Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!