Factory Wholesale Sewer Line - Api 5l Line Pipes Grade B To X70 Od From 219mm To 3500mm – Spiral
Factory Wholesale Sewer Line - Api 5l Line Pipes Grade B To X70 Od From 219mm To 3500mm – Spiral Detail:
The Mechanical Properties of the SSAW pipe
|
steel grade |
minimum yield strength |
minimum Tensile strength |
Minimum Elongation |
|
B |
245 |
415 |
23 |
|
X42 |
290 |
415 |
23 |
|
X46 |
320 |
435 |
22 |
|
X52 |
360 |
460 |
21 |
|
X56 |
390 |
490 |
19 |
|
X60 |
415 |
520 |
18 |
|
X65 |
450 |
535 |
18 |
|
X70 |
485 |
570 |
17 |
The Chemical composition of the SSAW pipes
|
steel grade |
C |
Mn |
P |
S |
V+Nb+Ti |
|
Max % |
Max % |
Max % |
Max % |
Max % |
|
|
B |
0.26 |
1.2 |
0.03 |
0.03 |
0.15 |
|
X42 |
0.26 |
1.3 |
0.03 |
0.03 |
0.15 |
|
X46 |
0.26 |
1.4 |
0.03 |
0.03 |
0.15 |
|
X52 |
0.26 |
1.4 |
0.03 |
0.03 |
0.15 |
|
X56 |
0.26 |
1.4 |
0.03 |
0.03 |
0.15 |
|
X60 |
0.26 |
1.4 |
0.03 |
0.03 |
0.15 |
|
X65 |
0.26 |
1.45 |
0.03 |
0.03 |
0.15 |
|
X70 |
0.26 |
1.65 |
0.03 |
0.03 |
0.15 |
The Geometric tolerance of the SSAW pipes
|
Geometric tolerances |
||||||||||
|
outside diameter |
Wall thickness |
straightness |
out-of-roundness |
mass |
Maximum weld bead height |
|||||
|
D |
T |
|||||||||
|
≤1422mm |
>1422mm |
<15mm |
≥15mm |
pipe end 1.5m |
full length |
pipe body |
pipe end |
T≤13mm |
T>13mm |
|
|
±0.5% |
as agreed |
±10% |
±1.5mm |
3.2mm |
0.2% L |
0.020D |
0.015D |
‘+10% |
3.5mm |
4.8mm |
Hydrostatic Test

The pipe shall withstand the hydrostatic test without leakage through the weld seam or the pipe body
Jointers need not be hydrostatically tested, providedthat the portions of pipe used in marking the jointers were successfully hydrostatically tested prior to the joining operation.
Traceablity:
For PSL 1 pipe, the manufacturer shall establish and follow documented procedures for maintaining:
The heat identity until each related chmical tests is performed and conformance with the specified requirements is shown
The test-unit identity until each related mechanical tests is performed and conformance with the specified requirements is shown
For PSL 2 pipe, the manufacturer shall establish and follow documented procedures for maintaining the heat identity and the test-unit identity for such pipe. Such procedures shall provide means for tracing any length of pipe to the proper test unit and the related chemical test results.
Product detail pictures:
Related Product Guide:
We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate in our success for Factory Wholesale Sewer Line - Api 5l Line Pipes Grade B To X70 Od From 219mm To 3500mm – Spiral , The product will supply to all over the world, such as: Latvia, Kenya, Sierra Leone, Our team knows well the market demands in different countries, and is capable of supplying suitable quality products at the best prices to different markets. Our company has already set up a professional, creative and responsible team to develop clients with the multi-win principle.